Heart Guardian HR-501 AED Machine
The Heart Guardian HR-501 AED Machine is a compact and portable Automated External Defibrillator designed to support emergency cardiac response. The device automatically analyzes the patient's ECG and provides guidance on whether an electrical shock is required. With voice prompts, audible beeps, LED visual guidance, adult and child controls, automatic self-testing, and Bluetooth data transfer, the HR-501 is designed for convenient AED operation in appropriate emergency environments.
The Heart Guardian HR-501 Automated External Defibrillator is a portable, battery-powered AED designed to support emergency response during sudden cardiac events. It automatically analyzes the patient's ECG and determines whether a defibrillation shock is indicated, helping guide the user through the appropriate stages of AED operation.
The HR-501 is designed with a straightforward control system featuring dedicated power, shock, and adult/child controls. Voice messages, audible beeps, and LED visual guidance help communicate operating instructions and device status during use.
The AED provides an output energy range of 50J to 150J, according to the supplied specifications. Its ECG analysis time is specified as approximately 8.5 seconds, while the high-capacity charging time is specified as approximately 8 seconds.
The HR-501 uses a lithium manganese battery system and is designed to provide extended operating capability. The supplied specifications indicate a shock capacity of at least 200 shocks, although actual battery performance depends on storage, operating conditions, battery condition, and device usage.
For data management, the AED can store up to 100 ECG records according to the supplied specifications. Bluetooth 2.0 connectivity allows supported data to be transferred from the device for appropriate review and management.
The HR-501 also incorporates automatic self-testing to help monitor the operational condition of the AED. Regular maintenance and readiness checks should still be performed according to the manufacturer's recommendations.
Its compact dimensions and approximately 1.9 kg device weight make it suitable for locations where portable emergency defibrillation equipment is required.
Portable Automated External Defibrillator
Model: HR-501
Automatic ECG analysis
Voice guidance and audible beeps
LED visual guidance
Adult and child operation controls
Easy age-mode selection
Disposable adhesive electrode pads
Automatic self-testing
Bluetooth 2.0 data transfer
ECG data storage
Compact and lightweight design
Battery-powered operation
CE certification
ISO 13485 certification
8-year main machine warranty against manufacturing defects, according to supplied information
The Heart Guardian HR-501 automatically analyzes the patient's ECG to determine whether a defibrillation shock is advised.
The supplied specification indicates an ECG analysis time of approximately 8.5 seconds. This automated analysis is designed to support the AED's decision-making process while guiding the user through the appropriate operating procedure.
The AED should always be used according to its instructions and applicable emergency response protocols.
The HR-501 provides multiple forms of user guidance, including:
Voice messages
Audible beeps
LED visual indicators
Picture-based guidance
These features are designed to make the operating sequence easier to follow during a high-pressure emergency situation.
The HR-501 includes dedicated controls for adult and child operation, allowing the appropriate mode to be selected according to the patient and the manufacturer's instructions.
The supplied product information also indicates that one pad set can be used across the specified age range, which may help simplify replacement accessory management. Users should always follow the manufacturer's instructions for pad application and patient selection.
The HR-501 provides a specified output energy range of 50J to 150J.
The appropriate energy delivery is controlled by the AED according to its operating system and selected patient mode. Users should follow the device's instructions and emergency response procedures during operation.
The HR-501 is powered by a lithium manganese battery system specified as Li-Mn, 12V DC, 4.2A.
The supplied specifications indicate a shock frequency of at least 200 shocks. Actual battery life and shock capacity can vary depending on battery condition, storage, environmental conditions, device operation, and other factors.
The HR-501 supports ECG data storage and can retain up to 100 ECG records according to the supplied specifications.
The device also supports Bluetooth 2.0 data transfer, providing a convenient method for transferring supported information for appropriate review and record management.
The AED incorporates an automatic self-testing function designed to help monitor the operational condition of the device.
Self-testing can assist with AED readiness monitoring, but routine physical inspection, battery checks, pad checks, and other maintenance procedures should still be performed according to the manufacturer's recommendations.
The HR-501 uses disposable adhesive electrode pads designed for AED defibrillation procedures.
The pads should be stored, maintained, and replaced according to the manufacturer's instructions. Always check the pad packaging and expiry information before relying on them for emergency use.
The HR-501 has a compact physical design measuring approximately 230 × 320 × 85 mm and a device weight of approximately 1.9 kg.
Its portable construction allows it to be placed in suitable emergency response locations where quick access to an AED is required.
The Heart Guardian HR-501 AED may be suitable for emergency preparedness in:
Hospitals
Clinics
Ambulances
Offices and workplaces
Schools and educational facilities
Sports and recreational facilities
Public-access AED locations
Healthcare facilities
Emergency response areas
Other appropriate locations requiring AED availability
Automatic ECG analysis
Clear voice and visual guidance
Adult and child operating controls
Portable and compact design
Automatic self-testing capability
Bluetooth data transfer
ECG data storage
50J–150J specified energy range
Battery-powered operation
Disposable adhesive electrode pads
CE and ISO 13485 certification
Long stated main-machine warranty
Product Type: Automated External Defibrillator (AED)
Model: HR-501
ECG Analysis Time: Approximately 8.5 seconds
High-Capacity Charging Time: Approximately 8 seconds
Output Energy: 50J–150J
ECG Data Storage: Up to 100 records
Data Transfer: Bluetooth 2.0
Control Buttons: Power / Shock / Adult-Child
Battery Type: Li-Mn
Battery Rating: 12V DC, 4.2A
Shock Capacity: At least 200 shocks, according to supplied specifications
Pad Type: Disposable adhesive electrode pad
Dimensions: 230 × 320 × 85 mm
Weight: Approximately 1.9 kg
Gross Weight: Approximately 3.8 kg
Carton Size: 34 × 35 × 18 cm
HS Code: 9018.90
Certification: CE / ISO 13485
Warranty: 8 years on the main machine against manufacturing defects, according to supplied information
Medilife Online Pharmacy provides convenient access to medical equipment and emergency preparedness products for healthcare facilities, workplaces, organizations, and other suitable environments.
The Heart Guardian HR-501 combines automatic ECG analysis, audio and visual guidance, adult and child controls, automatic self-testing, Bluetooth connectivity, and a compact portable design.
We provide clear product information to help customers understand AED equipment and select suitable emergency response solutions. For availability, electrode pads, batteries, warranty information, or technical specifications, customers can contact Medilife Online Pharmacy before ordering.
1. What is the Heart Guardian HR-501 AED used for?
The HR-501 is an Automated External Defibrillator designed to analyze a patient's ECG and provide guidance regarding whether a defibrillation shock is required during a cardiac emergency.
2. Does the HR-501 support both adults and children?
Yes. The device has dedicated adult and child controls for selecting the appropriate operating mode according to the patient and manufacturer's instructions.
3. What is the energy output of the HR-501?
The supplied specifications indicate an output energy range of 50J to 150J.
4. Does the HR-501 store ECG data?
Yes. The AED can store up to 100 ECG records according to the supplied specifications and supports Bluetooth 2.0 data transfer.
5. How long does the HR-501 take to analyze ECG information?
The supplied specification indicates an ECG analysis time of approximately 8.5 seconds. Actual operation can depend on the circumstances and device conditions.