Mesher Skin Expansion System

0 /5.0 (0 reviews)
Pricing
3,500.00D /AED

Minimum order qty 1

seller

Inhouse product

Message Seller
  • warranty check circle Cash on delivery available
Description

Mesher Skin Expansion System is a manually operated skin graft meshing system designed to create reticular skin grafts at different expansion ratios for appropriate skin graft procedures. The system uses interchangeable skin graft carriers to produce 1.5:1 and 3:1 expansion patterns without changing the expansion rollers. This design provides flexibility in graft preparation while helping reduce the need for multiple expansion rollers.

The system includes a main frame, continuous feed roller, cutting roller, ratchet handle, and four bags of skin graft carriers. Its durable construction is designed for professional clinical environments and appropriate sterilization processes.

Specifications

  • Product Type: Skin Graft Mesher

  • Operation: Manual

  • Function: Reticular skin graft preparation

  • Expansion Ratios: 1.5:1 and 3:1

  • Skin Graft Width: Up to 80 mm

  • Skin Graft Length: Unlimited

  • Graft Thickness: Unlimited

  • Expansion Method: Interchangeable ratio pattern carriers

  • Sterilization: Pre-vacuum steam, gravity displacement steam, or low-temperature plasma sterilization as applicable

  • Machine Construction: Durable, corrosion-resistant, self-lubricating materials

  • Packaging Size: 40 × 30 × 30 cm

  • Gross Weight: 9 kg

Standard Components

  • Main Frame – 1 Set

  • Continuous Feed Roller – 1 Pc

  • Cutting Roller – 1 Pc

  • Ratchet Handle – 1 Pc

  • Skin Graft Carriers – 4 Bags

Key Features

  • Designed for reticular skin graft preparation

  • Supports 1.5:1 and 3:1 expansion ratios

  • Different expansion ratios can be selected using corresponding skin graft carriers

  • Allows ratio changes without replacing the expansion rollers

  • Manual operating mechanism

  • Processes skin grafts up to 80 mm in width

  • Continuous feed roller supports controlled graft processing

  • Includes multiple skin graft carriers

  • Durable and corrosion-resistant construction

  • Suitable for appropriate professional clinical applications

Benefits

  • Provides flexibility for preparing different graft expansion ratios

  • Helps simplify the graft meshing process

  • Reduces the need to change expansion rollers when selecting different ratios

  • Supports consistent preparation of reticular skin grafts

  • Durable construction for professional healthcare environments

  • Multiple included carriers provide greater application flexibility

Applications

  • Skin graft preparation

  • Reticular skin graft production

  • Plastic and reconstructive surgical applications

  • Burn and wound care procedures where skin grafting is clinically indicated

  • Professional hospital and surgical environments

Cleaning, Sterilization & Maintenance

Follow the manufacturer's validated cleaning, sterilization, and maintenance procedures before and after use. The supplied specifications indicate compatibility with pre-vacuum and gravity displacement steam sterilization or low-temperature plasma sterilization, as applicable. Inspect the rollers, carriers, frame, and ratchet mechanism before use and ensure all components are properly assembled.

Safety Information

For use by qualified healthcare professionals trained in skin graft preparation and related surgical procedures. Follow the applicable clinical protocols and manufacturer's instructions for operation, sterilization, and maintenance. Do not use the system if any component is damaged or functioning improperly.

FAQs

1. What is a Mesher Skin Expansion System used for?
It is designed to prepare reticular skin grafts at different expansion ratios for appropriate skin graft procedures.

2. What expansion ratios are supported?
The system supports 1.5:1 and 3:1 reticular skin graft expansion ratios.

3. How are different expansion ratios selected?
Different ratios are produced by selecting the corresponding skin graft carrier, without changing the expansion rollers.

4. What is the maximum graft width?
The supplied specifications indicate that skin grafts up to 80 mm in width can be processed.

5. Is the system manually operated?
Yes, the system uses a manual operating mechanism.

Why Choose Medilife Online Pharmacy

Medilife Online Pharmacy provides professional medical and surgical equipment for hospitals, clinics, and healthcare facilities in the UAE. This Mesher Skin Expansion System offers a manual graft meshing solution with multiple carriers and expansion ratios for appropriate skin graft preparation applications.


Reviews & Ratings

0.0

Total Review 0

No reviews found!

Product Queries (0)

Login Or Registerto submit your questions to seller

Other Questions

No queries have been asked to the seller yet

Frequently Bought Together

No frequently bought products found!

About Medilife Online Pharmacy

All categories
Flash Sale
Todays Deal