The Autoclave Steam Sterilizer 100 L is a high-capacity automatic steam sterilization system designed for efficient sterilization of compatible medical and laboratory instruments. The DGL-100G features microcomputer control, adjustable sterilization parameters, automatic cold-air and steam discharge, drying function, safety interlock, digital display, and multiple protection systems for controlled and reliable operation.
The Autoclave Steam Sterilizer 100 L is designed to provide steam-based sterilization for suitable medical, laboratory, and healthcare applications. With a 100-litre chamber capacity, the DGL-100G provides a practical solution for facilities requiring larger-volume sterilization.
The sterilizer uses high-temperature steam under controlled pressure to sterilize compatible instruments and materials. Its microcomputer-based control system allows sterilization parameters to be set according to the requirements of the selected cycle and the manufacturer's operating instructions.
The unit is equipped with a drying function and provides automatic discharge of cold air before sterilization as well as automatic steam discharge after the sterilization process. A buzzer alerts the operator when the cycle is complete, followed by automatic shutdown.
For additional safety, the sterilizer incorporates protection functions for over-temperature, over-pressure, low water level, and dry heating. A safety interlock device is also included to help prevent unsafe operation.
The chamber is manufactured using high-quality stainless steel, and a stainless steel inner cylinder or compatible mesh basket configuration may be used depending on the selected setup.
The sterilizer features a digital display and touch buttons for operation, a standard test interface, a self-expanding seal, and a handwheel translation structure. An external printer and automatic water intake function are available as optional features.
100-litre steam sterilizer
DGL-100G model
Automatic steam sterilization
Microcomputer-controlled operation
Adjustable sterilization parameters
Drying function
Automatic cold-air discharge
Automatic steam discharge after sterilization
Automatic cycle completion buzzer
Automatic shutdown
Over-temperature protection
Over-pressure protection
Low water level protection
Anti-dry heating protection
Safety interlock device
Stainless steel chamber
Digital display
Touch-button controls
Standard test interface
Self-expanding seal
External printer option
Automatic water intake option
The DGL-100G provides a 100-litre chamber capacity, making it suitable for healthcare and laboratory facilities that require larger sterilization loads.
The chamber dimensions are specified as Ø450 × 615 mm, providing the internal space required for compatible sterilization items.
The sterilizer uses microcomputer-based automatic control, allowing sterilization parameters to be configured according to the requirements of the selected sterilization cycle.
The digital operating interface provides access to cycle information and controls through the display and touch buttons.
The specified sterilization temperature range is 116°C to 134°C, while the sterilization time can be set from 4 to 120 minutes.
The rated working temperature is 134°C, with a rated working pressure of 0.22 MPa.
Actual sterilization cycles should be selected according to the type of load, applicable sterilization requirements, and manufacturer's validated instructions.
The sterilizer includes a drying function designed to help remove residual moisture from compatible sterilized items after the sterilization cycle.
The drying time can be configured within the specified range of 0–240 minutes.
The unit automatically discharges cold air during the sterilization process and automatically releases steam after sterilization.
This automated operation helps simplify the sterilization cycle and reduce the need for manual intervention.
The DGL-100G incorporates multiple protective functions designed to support safer operation.
These include:
Over-temperature protection
Over-pressure protection
Low water level protection
Anti-dry heating protection
Safety interlock device
These features are intended to help protect the equipment and operator from specified abnormal operating conditions.
The sterilizer uses high-quality stainless steel material and includes a stainless steel inner cylinder or compatible basket configuration.
Stainless steel construction provides a durable and practical chamber material for repeated sterilization cycles when the equipment is correctly maintained.
The unit features a digital display and touch buttons designed to provide straightforward operation and monitoring.
The interface allows the operator to view available cycle information and adjust supported sterilization parameters.
Additional features are available as options, including:
External printer
Automatic water intake function
These options can be selected according to facility requirements and equipment configuration.
The Autoclave Steam Sterilizer 100 L may be suitable for:
Hospitals
Clinics
Medical centers
Dental facilities
Medical laboratories
Research laboratories
Healthcare sterilization departments
Surgical instrument sterilization
Laboratory instrument sterilization
Other appropriate steam sterilization applications
Large 100-litre sterilization capacity
Automatic steam sterilization cycles
Adjustable temperature and sterilization time
Integrated drying function
Automatic air and steam discharge
Multiple safety protection systems
Stainless steel chamber construction
Digital display and touch controls
Automatic cycle completion notification
Optional printing capability
Optional automatic water intake
Product Type: Autoclave Steam Sterilizer
Model: DGL-100G
Category: General Medical Products
Subcategory: Sterilization & Disinfection Equipment
Volume: 100 L
Power: 4.5 kW
Voltage: AC 110 V 60 Hz or AC 220 V 50 Hz
Design Pressure: -0.1 to 0.25 MPa
Design Temperature: 139°C
Rated Working Pressure: 0.22 MPa
Rated Working Temperature: 134°C
Sterilization Temperature Range: 116–134°C
Sterilization Time Range: 4–120 minutes
Drying Time Range: 0–240 minutes
Chamber Size: Ø450 × 615 mm
Bucket Dimension: Ø425 × 275 mm × 2
Optional Basket Dimension: Ø420 × 265 mm × 2
Outer Dimensions: 620 × 610 × 1275 mm
Packing Size: 690 × 650 × 1410 mm
Gross Weight: 144 kg
Net Weight: 113 kg
Display: Digital
Controls: Touch buttons
Sterilization Control: Microcomputer automatic control
Drying Function: Yes
Safety Interlock: Yes
Pressure Protection: Yes
Temperature Protection: Yes
Low Water Level Protection: Yes
Anti-Dry Heating Protection: Yes
External Printer: Optional
Automatic Water Intake: Optional
Medilife Online Pharmacy provides medical equipment and sterilization solutions for hospitals, clinics, dental facilities, laboratories, healthcare professionals, and other suitable healthcare environments.
The DGL-100G Autoclave Steam Sterilizer combines a large 100-litre chamber, automatic sterilization control, drying functionality, multiple safety protections, stainless steel construction, and digital operation for demanding sterilization environments.
Customers can contact Medilife Online Pharmacy for product availability, technical specifications, installation requirements, accessories, and usage-related information before ordering.
1. What is the capacity of the DGL-100G Autoclave?
The DGL-100G has a 100-litre chamber capacity.
2. What is the sterilization temperature range?
The specified sterilization temperature range is 116°C to 134°C.
3. How long can the sterilization cycle be set?
The specified sterilization time range is 4 to 120 minutes.
4. Does the autoclave have a drying function?
Yes. The sterilizer includes a drying function with a specified drying time range of 0–240 minutes.
5. What safety features are included?
The DGL-100G includes over-temperature protection, over-pressure protection, low water level protection, anti-dry heating protection, and a safety interlock device.
Steam sterilization equipment should be operated only by trained personnel according to the manufacturer's instructions, validated sterilization procedures, and applicable healthcare or laboratory standards.
Do not overload the chamber, and ensure that instruments, packaging materials, and other loads are compatible with steam sterilization. Proper loading, cycle selection, drying, and monitoring are essential for effective sterilization.
The chamber, seals, valves, water system, and safety functions should be inspected and maintained according to the manufacturer's recommended schedule.
Always verify electrical requirements, installation conditions, pressure ratings, and applicable local regulations before commissioning the equipment.
Frequently Bought Together
Products from this Seller
View All
Subscribe our newsletter for coupon, offer and exciting promotional discount..
Share with Friends
Trading is more effective when you share products with friends!Share you link
Share to