The CONTEC Baby Sound C1 Color Screen Fetal Doppler is a compact handheld fetal heart rate monitoring device designed to detect fetal heart activity using continuous-wave Doppler ultrasound technology. Its high-resolution color LCD displays fetal heart rate values, heartbeat waveforms, and a bar graph, while multiple operating modes and a comfortable crooked probe design provide flexibility for suitable prenatal monitoring in hospitals and clinics.
The CONTEC Baby Sound C1 Fetal Doppler is a handheld fetal heart rate detection device designed to support routine fetal heart monitoring during pregnancy. Using continuous-wave Doppler technology, the device detects fetal cardiac activity and provides visual and audible information for appropriate prenatal assessment.
The Baby Sound C1 features a high-resolution color LCD screen that can display the fetal heartbeat waveform, fetal heart rate (FHR) value, and a visual bar graph. This allows healthcare professionals to observe fetal heart activity through multiple forms of on-screen information.
The device provides three operating modes: Real-time FHR Display Mode, Averaged FHR Display Mode, and Manual Mode. This gives users flexibility when performing different types of fetal heart rate observations.
Its crooked probe design is intended to make probe positioning more convenient and comfortable during examination. The device also includes probe-fall detection and battery status indication to assist with routine operation.
For additional monitoring and documentation, the C1 includes an audio interface that can be connected to a compatible recording device through a recording cable, allowing fetal heart sounds to be recorded in real time.
The device operates using two AA batteries and can provide more than 8 hours of normal use according to the supplied product information.
Handheld fetal heart rate Doppler
High-resolution color LCD display
Fetal heart rate value display
Fetal heartbeat waveform display
FHR bar graph display
Real-time FHR display mode
Averaged FHR display mode
Manual operating mode
Crooked probe design
Probe-fall detection
Battery status indication
Automatic shutdown function
Audio recording interface
Real-time fetal heart sound recording capability
Portable and compact design
More than 8 hours of normal battery operation
The Baby Sound C1 features a high-resolution color LCD screen designed to provide clear visualization of fetal heart monitoring information.
The display can show:
Fetal heart rate value
Heartbeat waveform
FHR bar graph
When the FHR value is outside the configured normal range, the display provides a red alert indication according to the supplied product specifications.
The C1 provides three working modes:
Real-Time FHR Display Mode: Provides continuous visualization of the detected fetal heart rate.
Averaged FHR Display Mode: Displays an averaged fetal heart rate for suitable monitoring applications.
Manual Mode: Allows manual operation according to the examination requirements.
The device uses a crooked probe structure designed to make probe positioning easier during fetal heart rate examination.
The ergonomic probe shape is intended to provide greater handling convenience and a more comfortable user experience during appropriate monitoring.
The CONTEC Baby Sound C1 detects fetal heart activity using continuous-wave Doppler technology and calculates the fetal heart rate (FHR).
The combination of numerical FHR values, waveform information, and bar graph display provides multiple ways to observe the detected fetal cardiac activity.
The device can provide a visual red indication when the detected FHR value falls outside the configured normal range.
This feature is intended to draw attention to the displayed reading and should always be interpreted by a qualified healthcare professional in the context of the patient's clinical condition.
The Baby Sound C1 includes a probe-fall detection function designed to identify when the probe is disconnected or falls away from the intended measurement position.
This provides additional convenience during monitoring and can help users recognize when the probe position needs attention.
To help conserve battery power, the device can automatically shut down when no fetal heart signal is detected for approximately 1 minute, according to the supplied specifications.
The C1 provides an audio interface that can be connected to a compatible recording device using a recording cable.
This allows fetal heart sounds to be recorded in real time for suitable documentation or review purposes.
The fetal Doppler operates using two 1.5V AA (LR6) batteries.
According to the supplied information, the batteries can support more than 8 hours of normal use, depending on operating conditions and battery quality.
Nominal Frequency: 2.0 MHz
Working Frequency: 2.0 MHz ±10%
Comprehensive Sensitivity: ≥90 dB
Ultrasonic Output Power: <20 mW
Negative Peak Sound Pressure: <1 MPa
Output Beam Intensity: <20 mW/cm²
Spatial-Peak Temporal-Average Intensity: <100 mW/cm²
Working Mode: Continuous-wave Doppler
Effective Radiating Area of Transducer: <157 mm²
User manual – 1
2 MHz crooked probe – 1
1.3 MHz crooked probe
2.8 MHz vessel crooked probe
Optional probe availability should be confirmed according to the required application and product configuration.
Provides convenient fetal heart rate monitoring
Clear color display improves visibility of FHR information
Multiple working modes offer monitoring flexibility
Crooked probe design supports easier positioning
FHR waveform and bar graph provide additional visual information
Red alert indication highlights out-of-range FHR readings
Probe-fall detection supports convenient monitoring
Automatic shutdown helps conserve battery power
Audio interface supports real-time fetal heart sound recording
Compact design is convenient for clinical use
The CONTEC Baby Sound C1 may be suitable for:
Obstetrics and gynecology clinics
Hospitals
Maternity care facilities
Prenatal care centers
Medical examination rooms
Healthcare professionals
Suitable supervised prenatal monitoring
Product Type: Handheld Fetal Doppler
Model: Baby Sound C1
Technology: Continuous-Wave Doppler
Display: High-resolution color LCD
Monitoring: Fetal Heart Rate (FHR)
Display Information: FHR value, waveform and bar graph
Working Modes: Real-time FHR / Averaged FHR / Manual
Probe: 2 MHz crooked probe
Nominal Probe Frequency: 2.0 MHz
Working Frequency: 2.0 MHz ±10%
Comprehensive Sensitivity: ≥90 dB
Ultrasonic Output Power: <20 mW
Negative Peak Sound Pressure: <1 MPa
Output Beam Intensity: <20 mW/cm²
Ispta: <100 mW/cm²
Transducer Radiating Area: <157 mm²
Probe-Fall Detection: Supported
Battery: 2 × 1.5V AA LR6
Battery Life: More than 8 hours of normal use, according to supplied specifications
Automatic Shutdown: Approximately 1 minute without detected signal
Audio Interface: Supported
Color Display Alert: Red indication for out-of-range FHR
Medilife Online Pharmacy provides healthcare and medical equipment for hospitals, clinics, healthcare professionals, maternity care providers, and specialist medical facilities across the UAE.
The CONTEC Baby Sound C1 Color Screen Fetal Doppler combines portable fetal heart monitoring with a color display, multiple operating modes, ergonomic probe design, FHR alerts, data recording support, and practical battery operation.
We focus on providing clear product information, competitive pricing, convenient online ordering, and customer-focused support to help healthcare facilities and professionals select suitable medical equipment.
1. What is the CONTEC Baby Sound C1 Fetal Doppler used for?
The Baby Sound C1 is designed to detect and monitor fetal heart activity using continuous-wave Doppler ultrasound technology during suitable prenatal examinations.
2. What does the Baby Sound C1 display?
The device can display the fetal heart rate value, fetal heartbeat waveform, and an FHR bar graph on its color LCD screen.
3. What operating modes are available?
The C1 provides three modes: Real-time FHR Display, Averaged FHR Display, and Manual Mode.
4. Does the Baby Sound C1 have an automatic shutdown function?
Yes. The device can automatically shut down after approximately 1 minute without a detected signal, helping conserve battery power.
5. Can fetal heart sounds be recorded?
Yes. The device includes an audio interface that can connect to a compatible recording device through a suitable recording cable for real-time fetal heart sound recording.
The CONTEC Baby Sound C1 is a fetal monitoring device intended for appropriate prenatal applications and should be used according to the manufacturer's instructions and professional medical guidance.
Detection of fetal heart activity does not by itself confirm fetal well-being and should not replace routine prenatal examinations or professional clinical assessment. Any concerning symptoms or abnormal findings should be evaluated by a qualified healthcare professional.
Frequently Bought Together
Products from this Seller
View All
Subscribe our newsletter for coupon, offer and exciting promotional discount..
Share with Friends
Trading is more effective when you share products with friends!Share you link
Share to