Surtron Electrosurgical Unit HP 50D

0 /5.0 (0 reviews)
Pricing
3,600.00D /AED
4,000.00D
-10%

Minimum order qty 1

seller

Inhouse product

Message Seller
LED Spa

Brand LED Spa

Products from this brand
  • warranty check circle Cash on delivery available

Surtron Electrosurgical Unit HP 50D

The Surtron Electrosurgical Unit HP 50D is a professional radiofrequency electrosurgical system designed for monopolar microsurgery. It provides dedicated CUT and COAGULATION functions, an intuitive touchscreen interface, programmable work settings, and advanced safety controls. With adjustable output power and a universal 100–240 Vac input, the HP 50D is suitable for professional surgical environments.

Description

The Surtron HP 50D Electrosurgical Unit is a compact and advanced radiofrequency electrosurgical generator designed to support monopolar surgical procedures. It combines controlled electrical output, intuitive operation, and safety monitoring in a practical system for professional healthcare environments.

The unit provides separate CUT and COAGULATION functions, allowing healthcare professionals to select the appropriate operating mode according to the procedure and clinical requirements. Different working programs can also be selected and saved, helping streamline repeated procedures and improve workflow efficiency.

The HP 50D features a user-friendly touchscreen interface that allows convenient control of the available functions and operating settings. Its output power monitoring and self-check controls are designed to support safe and reliable operation.

With a working frequency of 600 kHz and selectable input voltage from 100 to 240 Vac, the system is designed to operate across different power supply environments without requiring major electrical modifications.

The compact dimensions and approximately 2.5 kg weight make the Surtron HP 50D a practical choice for operating rooms and surgical facilities where space-efficient electrosurgical equipment is required.

Key Features
  • Professional radiofrequency electrosurgical unit

  • Designed for monopolar microsurgery

  • CUT and COAGULATION operating functions

  • Intuitive touchscreen interface

  • Selectable and savable work programs

  • Output power monitoring

  • Integrated self-check control

  • 600 kHz working frequency

  • Selectable 100–240 Vac input voltage

  • 50–60 Hz mains frequency

  • Compact and lightweight design

  • Designed for professional surgical environments

  • Supports underwater cutting and coagulation applications

CUT Function

The Surtron HP 50D provides multiple CUT power settings for controlled monopolar electrosurgical applications.

The available maximum output levels include:

  • CUT: 50 W at 400 Ω

  • CUT 1: 45 W at 400 Ω

  • CUT 2: 40 W at 400 Ω

The selectable settings provide flexibility for different surgical requirements and procedural preferences.

COAGULATION Function

The HP 50D also provides a dedicated COAGULATION function with a maximum output of:

  • COAG: 40 W at 400 Ω

The coagulation mode is designed for compatible monopolar electrosurgical applications where controlled coagulation is required.

Touchscreen Operation

The intuitive touchscreen interface provides convenient access to the system's operating functions and settings.

The touchscreen-based design helps simplify daily operation while allowing healthcare professionals to select appropriate programs and adjust available parameters according to procedural requirements.

Programmable Work Programs

The HP 50D allows users to select and save different work programs.

This feature can help improve workflow efficiency by allowing frequently used operating configurations to be stored for appropriate procedures.

Output Monitoring & Self Check

The electrosurgical unit incorporates output power monitoring and a self-check control to support reliable system operation.

These functions are designed to help monitor the equipment during use and identify operational conditions that may require attention.

Universal Power Compatibility

The HP 50D supports a selectable input voltage range of 100–240 Vac and mains frequencies of 50–60 Hz.

Its switching technology is designed to accommodate different electrical supply environments without requiring system modifications.

Underwater Cutting & Coagulation

The Surtron HP 50D supports underwater cutting and coagulation applications, providing additional versatility for suitable surgical procedures where this operating technique is required.

Use of underwater electrosurgery should always follow the manufacturer's instructions and appropriate clinical protocols.

Benefits
  • Supports controlled monopolar electrosurgery

  • Provides dedicated cutting and coagulation functions

  • Multiple CUT settings offer procedural flexibility

  • Touchscreen operation simplifies equipment control

  • Programmable work settings can improve workflow

  • Output monitoring supports controlled operation

  • Self-check functionality supports equipment readiness

  • Compact design helps save operating-room space

  • Universal input voltage supports flexible installation

  • Suitable for professional surgical environments

Applications

The Surtron HP 50D can be suitable for professional medical environments requiring monopolar electrosurgery, including:

  • Operating rooms

  • Surgical departments

  • Hospitals

  • Medical clinics

  • Day-surgery facilities

  • Specialist surgical centers

  • Electrosurgical procedure rooms

Technical Specifications
  • Product Type: Electrosurgical Unit

  • Model: SURTRON TOUCH HP 50D

  • Technology: Radiofrequency electrosurgery

  • Primary Application: Monopolar microsurgery

  • Operating Functions: CUT and COAGULATION

  • Maximum CUT Output: 50 W at 400 Ω

  • CUT 1 Output: 45 W at 400 Ω

  • CUT 2 Output: 40 W at 400 Ω

  • Maximum COAG Output: 40 W at 400 Ω

  • Working Frequency: 600 kHz

  • Patient Circuit: Type F

  • Input Voltage: 100/240 Vac

  • Mains Frequency: 50–60 Hz

  • Electrical Input Power: 200 VA

  • Dimensions (W × H × D): 190 × 85 × 239 mm

  • Weight: 2.5 kg

  • Controls: Output power monitoring, self-check control

  • Electrical Class: Class I, CF

Safety & Compliance

The Surtron HP 50D is specified with compliance to the following standards:

  • EN 60601-1

  • EN 60601-1-2

  • EN 60601-2-2

The device is classified as Electrical Class I, CF.

According to the supplied product information, its MDR 2017/745/EU classification is Class IIb.

Why Choose Medilife Online Pharmacy

Medilife Online Pharmacy provides medical equipment and surgical technology for hospitals, clinics, healthcare professionals, and healthcare facilities.

We focus on providing clear product information so healthcare buyers can evaluate equipment according to their clinical and operational requirements. For electrosurgical equipment such as the Surtron HP 50D, customers can contact Medilife Online Pharmacy for product availability, specifications, compatible accessories, and purchasing assistance.

Frequently Asked Questions

1. What is the Surtron HP 50D used for?

The Surtron HP 50D is a radiofrequency electrosurgical unit designed primarily for monopolar microsurgery and provides CUT and COAGULATION functions.

2. What cutting modes are available on the HP 50D?

The unit provides three listed cutting output settings: CUT, CUT 1, and CUT 2, with maximum outputs of 50 W, 45 W, and 40 W respectively at 400 Ω.

3. Does the Surtron HP 50D have a touchscreen?

Yes. The HP 50D features an intuitive touchscreen interface for controlling available operating functions and settings.

4. What is the maximum coagulation output?

The specified maximum COAGULATION output is 40 W at 400 Ω.

5. What power supply does the HP 50D support?

The unit has a selectable input voltage of 100/240 Vac and supports a mains frequency of 50–60 Hz.

Important Safety Information

The Surtron HP 50D is professional electrosurgical equipment and should only be installed, operated, and maintained by appropriately trained healthcare professionals.

Always follow the manufacturer's instructions, applicable clinical protocols, and relevant medical-device regulations. Electrosurgical procedures should be performed using appropriate compatible accessories and safety precautions.


Reviews & Ratings

0.0

Total Review 0

No reviews found!

Product Queries (0)

Login Or Registerto submit your questions to seller

Other Questions

No queries have been asked to the seller yet

Frequently Bought Together

No frequently bought products found!

About Medilife Online Pharmacy

All categories
Flash Sale
Todays Deal